Features
|
|
Specifications
Voltage DC
Range:
6.000V - 1000V
Best Accuracy:
+/- (0.3% + 1)
Best Resolution:
0.1 mV
Voltage AC
Range:
600.0 mV-1000V
Best Accuracy:
+/- (2.0% + 2)
Best Resolution:
1.0 mV
Amps AC
Range:
60.00 mA – 10A
Best Accuracy:
+/- (1.5% + 2)
Best Resolution:
0.01mA
Amps DC
Range:
60.00 mA – 10A
Best Accuracy:
+/- (2.5% + 2)
Best Resolution:
0.01 mA
Resistance
Range:
600.0 Ω - 50 MΩ
Best Accuracy:
+/- (0.5% + 1)
Best Resolution:
0.1Ω
Capacitance
Range:
1nF- 9,999 µF
Best Accuracy:
+/- (1.2% + 2)
Best Resolution:
1 nF
Frequency
Range:
99.99Hz- 99.99kHz
Best Accuracy:
+/- (0.1% + 1)
Best Resolution:
0.01Hz
Safety
ANSI/ISA S82.02.01, CSA C22.2-1010.1, IEC 61010 to 1000 V Measurement Category III, 600 V Measurement Category IV
Certifications
CSA, TÜV (EN61010), UL, Π, ; (N10140),VDE
Maximum voltage
1000V between any terminal and earth ground
Surge protection
8 kV peak per IEC 61010
Ω Fuse for mA inputs
440 mA, 1000 V FAST Fuse
Ω Fuse for A inputs
11 A, 1000 V FAST Fuse
Display
Digital:
6000 counts, updates 4/sec
Bar Graph:
33 segments; Updates 32/sec
Frequency:
10,000 counts
Capacitance:
1,000 counts
Altitude
Operating:
2,000 meters
Storage:
12,000 meters
Temperature
Operating:
-10 °C to +50 °C
Storage:
-40 °C to +60 °C
Temperature Coefficient
0.1 X (specified accuracy / °C (< 18 °C or > 28 °C)
Electromagnetic Compatibility (EN 61326-1:1997)
In an RF field of 3 V/M, accuracy = specified accuracy except in temperature: specified accuracy ± 5 °C (9 °F)
Relative Humidity (Maximum Non-condensing)
90 % to 35 °C
75 % to 40 °C
45 % to 50 °C
Battery Life
400 hours typical (alkaline)
Size
Height:
4.3 cm
Width:
9.0 cm
Length:
18.5 cm
Weight
420 g
|
||
![]() |
![]() |
![]() |
The Fluke TPAK ToolPak universal hanger attaches to the meter and can be used by itself on a nail, hook, with a piece of rope or stiff wire. | Two hook-and-loop straps are used with the TPAK ToolPak universal hanger and can be wrapped around a pipe or beam. | ToolPak’s magnet is used with the universal hanger and is strong enough to securely hold you meter. |
|
|