Performance Testing: For direct burial according to UL 486D test standard.
Application
For use in low voltage wiring, including cathodic protection systems, test leads, tracer wire, landscape irrigation, landscape lighting, and golf. Dimensions
A
2.00"
B
0.540"
C
0.813"
D
0.547"
Installation
Important: Turn off power before installing or removing connector. Product to be used in accordance with local and national codes.
Strip wires 1/2".
Align frayed strands or conductors.
NO pre-twisting needed. Hold wires together with ends even. Note: Twist and lead stranded wires slightly.
Push wires firmly into connector when starting.
Twist connector onto wires pushing firmly until tight. Do not over-torque.