Farwest oil cooled cathodic protection rectifiers, manufactured by Universal Rectifiers, Inc., are recognized as industry leading in quality, workmanship and service life. Many years of field-proven service have led to the superior design of these rectifiers. Conservative equipment ratings, controlled manufacturing techniques, plus many extra features ensure long and trouble-free operation.
Typical cathodic protection applications for the oil cooled rectifier line include severe environmental conditions due to high humidity, dust, or other situations that would shorten the life of a standard air cooled rectifier.
Explosion proof models are used for Class 1, Group D locations and comply with U.L. Standard 698. While similar to the standard oil cooled rectifiers, the explosion proof units are fitted with special hazardous area fittings to eliminate possibility of an ignition source.
Configure an 8-position model number like OSOI 50-30 CBC Positions from left to right are as follows:
Position #1: Model
O = Standard Line, Oil cooled
Position #2: Type
S = Standard Rectifier (Manual taps) C = Constant Current (Reactor style) D = Constant Current (Solid state) E = Constant Voltage (Solid state)
P = Constant potential (solid state) I = Constant potential IR free (solid state) M = Multiple Modes (Specify Modes Required) V = Variac control
Position #3: Cooling
O = Oil Cooled Standard
X = Oil Cooled (Hazardous Location) Class 1, Div. 2
Position #4: Stack Type
I = Silicon (recommended) E = Selenium
Position #5: DC Volts
List Maximum DC Voltage Desired
Position #6: DC Amps
List Maximum DC Amperage Desired
Position #7: AC Input
AA = 115/230, 1 phase set for 115 vac BA = 230/460, 1 phase set for 230 vac CA = 230/460, 3 phase set for 230 vac EA = 115/460, 1 phase set for 115 vac G = 115, 1 phase only H = 230, 1 phase only
AB = 115/230, 1 phase set for 230 vac BB = 230/460, 1 phase set for 460 vac CB = 230/460, 3 phase set for 460 vac EB = 115/460, 1 phase set for 460 vac D = 208, 3 phase F = Specify
Position #8: Special Features
C = AC and DC arrestors D = DC arrestor E = AC arrestor F = Filter choke G = Communications filter H = Meter switches* J = Power On indicator light
K = DC failure warning light M = DC breaker (> 100 amps) or fuse P = Additional voltage control link bar taps R = 115 VAC convenience outlet S = Multiple circuits (qty.) W = RMU Terminal Strip Z = Other, specify