Farwest Corrosion
Control Company
 

Home Products Services Contact Us Request Quote Order Online

 
 

 Navigation:  Home > Products > Galvanic Anodes > Anodes - Zinc

Technical Practices for PLATTLINE™
Zinc Ribbon Anode Connections

Plattline Zinc Ribbon Anode Connection Practices for

Buried Pipelines
Above Ground Storage Tanks
AC Mitigation Systems
Other Systems

Plattline zinc ribbon anodes are used in a variety of applications. They are used in cathodic protection on buried pipelines, sacrificial cathodic protection of secondary bottoms on above ground storage tanks, as grounding mats for AC current mitigation, and in other corrosion protection applications.

During installation procedures of Plattline zinc ribbon anodes in the above applications, it is necessary to connect Plattline to itself and to other main cables for full electrical interconnection of current flow. These connection procedures are illustrated in this bulletin for easy reference. This guide should prove to be helpful to management and field personnel involved with the application and installation of Plattline zinc ribbon anodes. Plattline zinc ribbon anodes are manufactured with a steel wire core for electrical path continuity and for strength and handling of the product. This steel wire core is firmly bonded to the product.

To expose the steel wire core, melt the zinc off using a suitable torch which is capable of providing over 1000°F (Reasonable care should be exercised to insure safe operation when melting any metal). The steel wire core can be exposed using this procedure at the ends of a length of Plattline or in the middle of a run of Plattline.

The exposed core is readily connected to itself as shown in Figure 1 and to another cable as shown in Figure 2. Procedures for each connection are given with the each illustration. Plattline™ zinc ribbon anodes come in four sizes as shown in Table 1. Each size of Plattline™ can be connected in the same fashion.

Procedure

1. Remove 1-1/2" of zinc from iron wire core at ends of anode ribbons to be spliced.
2. Join two ends of iron wire cores together.
3. Insert iron wire core ends into cad welder.
4. Open cover and place metal disk into mold pocket. Open Cadweld charge No. CA-15, pour outweld metal and starting powder into mold.
5. Close cover and ignite powder charge with flint gun.
6. After weld has cooled, remove weld slag from connection..
7. Wrap exposed iron wire core, weld connection and 1" of zinc anode ribbon (each end) with two half-lapped layers of rubber tape and two halt/lapped layers of plastic tape.
Crimp Connection Procedure


Figure 1. Crimp connection

1. Remove 1-1/2"of zinc from steel wire core at ends of Plattline to be spliced.
2. Join two ends of steel wire cores together.
3. Insert copper compression connector into installation tool.
4. Insert core wire ends into copper compression connector.
5. Crimp according to instructions with installation tool.
6. Wrap exposed steel wire core, connector and 1" of Plattline (each end) with insulated splice kit or with two half-lapped layers of rubber tape and two half-lapped layers of plastic tape.

Figure 2. Detail of Anode-to-header cable splice

1. Remove 3" of zinc from iron core of anode ribbon.
2. Strip 3 1/2" of insulation from insulated copper cable without breaking copper strands.
3. Insert copper compression connector into jaws of installation tool.
4. Slip connector over both Plattline steel core and copper cable.
5. Crimp using recommended procedure with installation tool.
6. Wrap entire completed connection, including 1" of Plattline (each end) with insulated splice kit or with two half-lapped layers of rubber tape and two half-lapped layers of plastic tape.

Product Specifications

Plattline zinc ribbon anodes are used in a variety of applications. They are used for cathodic protection on buried pipelines, for AC mitigation on pipelines, for sacrificial cathodic protection of secondary bottoms on above-ground storage tanks, for AC mitigation grounding mats and for other corrosion protection applications.

  • Plattline I is an alloyed zinc product and generally used in seawater or brackish water systems. It meets the chemical requirements of MIL-A-18001K and ASTM B418-95a Type 1.
      
  • Plattline II is a high purity product and generally used in underground and fresh water systems. It meets the chemical requirements of ASTM B418-95a Type II.
      

Product
Size

platt09.gif (1631 bytes)
Super

platt10.gif (1406 bytes)
Plus

platt11.gif (1245 bytes)
Standard

platt12.gif (1085 bytes)
Small

  Cross section 1" x 1-¼"
25.4 x 31.75 mm
5/8" x 7/8"
15.88 x 22.22 mm
1/2" x 9/16"
12.7 x 14.28 mm
11/32" x 13/32"
8.73 x 10.32 mm
  Weight 2.4 lbs/ft
3.570 kg/m
1.2 lbs/ft
1.785 kg/m
0.6 lbs/ft
0.8925 kg/m
0.25 lbs/ft
0.372 kg/m
  Diameter of
  wire core
0.185"
4.70 mm
0.135"
3.43 mm
0.130"
3.30 mm
0.115"
2.92 mm
  Coil length,
  standard
100 ft
30.5 m
200 ft
61 m
500 ft
152 m
1000 ft
305 m
  Coil I.D.,
  standard
36"
91.44 cm
36"
91.44 cm
12"
30.5 cm
12"
30.5 cm
  Packaging Steel banded, random wound open coils. Steel banded, random wound open coils. Wood reels Wood reels
    
   Footnotes to Specifications Table
  1. All dimensions and weights are nominal.
  2. Galvanized Steel.
  3. "Arctic" standard size has nominal core diameter of .163" (4.140 mm).
  4. Longer coil lengths are available on special order.
  5. Standard size also available in reels of 1000 ft and 3600 ft.
  6. Plattline I is an alloyed zinc product and is generally used in seawater or brackish water systems. It meets the chemical requirement of MIL-A-18001K and ASTM B418-95a Type I.
  7. Plattline II is a high purity product and generally used in underground and fresh water systems. It meets the chemical requirements of ASTM B418-95a Type II.
      

Cathodic Protection Products & Materials

  

Cathodic Protection Services

 Farwest Engineering
 Farwest Installation

  

Cathodic Protection of Offshore Structures

 Galvanic CP Systems
 Impressed CP Systems
 Attachment Systems
 Monitoring Equipment

  

Marine Products Division

 Marine ICCP Systems
 Galvanic CP Materials
 Marine Anti-Fouling
 Electrolytic De-Scaling
 Electro-Chlorination
 Marine CP Monitoring
 Galvanic Isolators

  

Corrosion Control Products Company

  

More Farwest
Website Resources

 Farwest News
 Search this Website
 Request Quote
 Order Products Online
 

Home

Products Services Search Request Quote Order Online

Farwest Corrosion Control Company
888-532-7937   (888-5FARWEST)
Complete Cathodic Protection™

Tel: 

 310-532-9524
Fax:  310-532-3934

1480 West Artesia Blvd., Gardena, CA 90248-3215, USA
 www.farwestcorrosion.com

© 1996-2009 Farwest Corrosion Control Company | Privacy Statement
 

Integrity – Service – Quality
                  
... Since 1956